BL1000 LCD
-
Automatic Voltage Regulation (AVR)
-
LCD Display
-
Generator compatible
- 2-year UPS warranty
- Free delivery within Ho Chi Minh City, with fast delivery in 2–4 hours
- Free installation support in Ho Chi Minh City
- Dealer Support:
0906 336 500
Warranty Support:
0903 808 500
UPS Sorotec BL1000 LCD is designed to provide reliable power protection for office equipment such as computers, network switches, WiFi routers, and surveillance cameras. The unit utilizes Line Interactive (Offline) technology with a built-in Automatic Voltage Regulator (AVR) to minimize the risk of equipment damage caused by unstable power conditions such as voltage sags, surges, or fluctuations, while also helping to extend battery life.
LCD indicators display utility Input/output voltage, UPS load percentage, battery capacity, and operating status (utility mode or battery backup mode). Additional features include overload protection and audible alarms, enabling users to respond promptly to any faults. The compact design allows for easy installation, saves space, and is well suited for offices and small workspaces.
|
|
Key features |
- AC mode efficiency up to 98%, with power factor (PF) of 0.6
- Wide input voltage range and high input power factor
- LCD display: Input/output voltage, UPS load percentage, battery capacity, and operating status (utility mode or battery backup mode).
- Audible low battery alarm
- Low noise operation
- Self-test function at startup
- Automatic charging in both ON and OFF modes
- Automatic input frequency sensing
- Microprocessor-controlled UPS operation and power management
- Generator compatible
- Automatic restart when utility power is restored
- Suitable for low-power devices such as modem, switch, Wi-Fi router, LED lighting, etc.
- Built-in AVR (Automatic Voltage Regulation) function
- Automatically switches to battery mode during over-voltage or under-voltage conditions
- Protection against over-voltage, under-voltage, short circuit, and overload
- USB communication port for computer connection (optional)
- Optional Power Manager software for UPS monitoring, automatic computer shutdown and UPS/computer power management
| INPUT | |
|---|---|
| Rated Voltage | 220Vac |
| Input Voltage Range | 145 - 290Vac |
| Rated Frequency | 50/60Hz (40 - 65Hz) |
| OUTPUT | |
| Capacity | 1000VA/600W |
| Output Voltage | 220Vac ±10% |
| Waveform (Battery Mode) | Simulated sine wave |
| Output Frequency (Battery Mode) | 50Hz ± 0.5Hz |
| Transfer Time | 4 ~ 6 ms |
| Output Power Factor | 0.6 |
| Output Socket Type | IEC Universal × 4 & C13 × 3 |
| BATTERY | |
| Battery Type | Sealed lead-acid battery |
| Battery | 12V7.2Ah × 2 |
| BACKUP TIME | |
| Battery Mode | UPS automatically shuts down when battery is low |
| Desktop PC + 24” Monitor × 1 | 55 minutes |
| Desktop PC + 24” Monitor × 2 | 22 minutes |
| Backup Time at 25% Load | 34 minutes |
| Backup Time at 25% Load | 11 minutes |
| MANAGEMENT & COMMUNICATION | |
| Control Panel | Power on/off button, LCD indicators |
| Alarm | Input/output voltage, UPS load percentage, battery capacity, and operating status (utility mode or battery backup mode) |
| Communication Port | USB port (Optional) |
| Software | Power Manager software for monitoring, automatic shutdown and system management on all Windows OS (Optional) |
| OPERATING ENVIRONMENT | |
| Operating Temperature | 0 ~ 45°C (non-condensing) |
| Operating Humidity (non-condensing) | 10 ~ 90% |
| PHYSICAL DIMENSIONS | |
| Dimensions (D × W × H) (mm) | 330 x 120 x 190 ± 2% |
| Net Weight (Kg) | 8.85 ± 2% |